========================================================================== The checksum's (found through sum -r) of the files that you have received (other than this README) are as follows: 61864 2 patchSG0002271 42284 147 patchSG0002271.eoe_sw 13474 2 patchSG0002271.idb ========================================================================== - 1 - 1. Patch_SG0002271_Release_Note This release note describes patch SG0002271 to IRIX 6.2. Patch SG0002271 replaces patch SG0001825. 1.1 Supported_Hardware_Platforms This patch contains bug fixes for Indy XZ systems. It can also be installed on Indigo2 Extreme or XZ systems, and will not cause any problems, but the bugs it fixes are not seen on those systems. The software cannot be installed on other configurations. 1.2 Supported_Software_Platforms This patch contains bug fixes for IRIX 6.2 (version 1232792137) and IRIX 6.2 with IMPACT 10000 (version 1233007732). The software cannot be installed on other configurations. 1.3 Bugs_Fixed_by_Patch_SG0002271 This patch contains fixes for the following bugs in IRIX 6.2. Bug numbers from Silicon Graphics bug tracking system are included for reference. o Indy XZ systems may miss bytes when reading from the serial ports while complex graphics applications are active. (Bug #456421) 1.4 Subsystems_Included_in_Patch_SG0002271 This patch release includes these subsystems: o patchSG0002271.eoe_sw.gfx 1.5 Installation_Instructions Because you want to install only the patches for problems you have encountered, patch software is not installed by default. After reading the descriptions of the bugs fixed in this patch (see Section 1.3), determine the patches that meet your specific needs. If, after reading Sections 1.1 and 1.2 of these release notes, you are unsure whether your hardware and software meet the requirements for installing a particular patch, run inst. The inst program does not allow you to install patches that are incompatible with your hardware or - 2 - software. Patch software is installed like any other Silicon Graphics software product. Follow the instructions in your Software Installation Administrator's Guide to bring up the miniroot form of the software installation tools. Follow these steps to select a patch for installation: 1. At the Inst> prompt, type install patchSGxxxxxxx where xxxxxxx is the patch number. 2. Initiate the installation sequence. Type Inst> go 3. You may find that two patches have been marked as incompatible. (The installation tools reject an installation request if an incompatibility is detected.) If this occurs, you must deselect one of the patches. Inst> keep patchSGxxxxxxx where xxxxxxx is the patch number. 4. After completing the installation process, exit the inst program by typing Inst> quit 1.6 Patch_Removal_Instructions To remove a patch, use the versions remove command as you would for any other software subsystem. The removal process reinstates the original version of software unless you have specifically removed the patch history from your system. versions remove patchSGxxxxxxx where xxxxxxx is the patch number. To keep a patch but increase your disk space, use the versions removehist command to remove the patch history. versions removehist patchSGxxxxxxx - 3 - where xxxxxxx is the patch number. 1.7 Known_Problems